1-5-25 SMDR Valid Call Time Assignment
General Description
Use this Memory Block to assign the minimum call time before the Station Message
Detail Recording (SMDR) outputs a record of the outgoing CO/PBX call.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK5 +
BE
to access the Memory Block.
3 Use the dial pad to enter data.
Minimum time assignment is 000 sec.
Time assignment can be set from 000~099 sec. in increments of 10.
Default Values
040 seconds
4 Press G to write the data. The next Memory Block is displayed.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-05
Start Time Selection
1-5-13
Printer Connected Selection
System Mode
1
Submode
5
Data No.
25