Electra Elite IPK Document Revision 4
Programming Manual 2 - 67
___________________________________________________________________________________
___________________________________________________________________________________
1-1-51 CO Line Ringing Pattern Selection
General Description
Use this Memory Block to assign the initial ringing pattern or no ring for incoming calls
on a CO line.
Display
Settings
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
A B C D E F G H
LK 9 LK 10 LK 11 LK 12 LK 13 LK 14 LK 15 LK 16
NO
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
EA
to access the Memory Block.
3 Press corresponding CO/PBX line key to change data.
Use the following to enter data:
C to access the next page
A to access the previous page
4 Press
G to write data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-59
Synchronous Ringing Selection
System Mode
1
Submode
1
Data No.
51
PC Programming
¦
+BCS
Title
5 1 : C O P T N A | 1
T I M E D I S P L A Y
Data
No.
Setting
Data
Page
No.