1-4-04 Tandem Transfer SMDR Print
Extension Assignment
General Description
Use this Memory Block to specify a special number to be output from Station Message
Detail Recording (SMDR) to indicate an automatic trunk-to-trunk transfer.
Display
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK4 +
JD
to access the Memory Block.
3 Use the dial pad to enter the Table Number and Setting Data.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
Setting Data (Allowed):
2-Digit Number: 10~89
3-Digit Number: 100~899
4-Digit Number: 1000~8999
4 Press G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-2-03
2-, 3-, or 4-Digit Station Number Selection
1. When the system is powered up initially, this Memory Block defaults to 3-digit number 999.
2. When 2-digit station numbers are selected, this Memory Block defaults to 99.
3. When 4-digit station numbers are selected, this Memory Block defaults to 9999.
System Mode
1
Submode
4
Data No.
04
PC Programming
¦
+AT
0 4 : T A N D E X T = 9 9 9
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
Default Values
3-digit number = 999