2 - 158 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Display (R3000 or higher)
Related Programming
Refer to individual features in the Electra Elite IPK Features and Specifications Manual.
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
J
+
C
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
001s~255s (e.g., 180s =3min)
Default Values
120s
4 Press G to write the data and display the next Memory Block.
5 Program the next Memory Block, or press
E to go back on-line.
1. When the called party does not answer in the programmed time, the call is dropped.
2. R3000 or higher is required to adjust this Memory Block by 1-second intervals.
0 3 : A A D I S C 1 2 0 s
T I M E D I S P L A Y
Setting
Data
Data
No.
Title