Electra Elite IPK Document Revision 4
Programming Manual 2 - 191
___________________________________________________________________________________
___________________________________________________________________________________
1-7-00 Doorphone Assignment
General Description
Use this Memory Block to enable the doorphones in System Programming.
Display
Settings
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
Default not
assigned.
DPH1 DPH2 DPH3 DPH4
Programming Procedures
1 Go off-line.
2 Press LK1 + LK7 to access the Memory Block.
3 Press the CO/PBX line key corresponding to each doorphone. The LED changes to indicate the data each time the CO/PBX line
key is pressed.
4 Press
G to write the data. The next Memory Block is displayed.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-7-01
Doorphone Display Time Selection
System Mode
1
Submode
7
Data No.
00
PC Programming
¦
+BTP
0 0 : D P H A S S I G N
T I M E D I S P L A Y
Title
Data
No.
CO/PBX
Line LED
Off On
Data
No Yes
The shaded area is the
default setting.