1-15-02 Common Signal Channel Assignment
General Description
Use this Memory Block to assign a T1 Trunk to be a Common Signaling Channel.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK15 +
KB
to access the Memory Block.
3 Use dial pad keys to enter Setting Data.
Use the following to enter data:
J
to move cursor left
L
to move cursor right
K
~
I
to enter numeric data
Default Values
:
00
4 Press G to write the data.
5 Press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1
Card Interface Slot Assignment
7-3-01
MIF (LCR) Assignment
7-3-02
MIF (SMDR) Assignment
1-15-00
K-CCIS Main/Remote Office Selection
1-15-01
Common Signal Channel Data Speed Assignment
1-15-03
Originating Point Code Assignment
1-15-04
Destination Point Code Assignment
1-15-05
Destination Point Code Transfer Assignment
1-15-06
Originating Office Code Number Assignment
1-15-07
K-CCIS Message Response Timeout Assignment
1-15-08
Link Reconnect Allow/Deny Selection
1-15-09
K-CCIS Maximum Call Forwarding Hop Assignment
System Mode
1
Submode
15
Data No.
02
PC Programming
¦
+AW
0 2 : C S C 1 = C O 0 0
T I M E D I S P L A Y
Title
Setting
Data
Data
No.
C-Channel
1~4