Electra Elite IPK Document Revision 4
Programming Manual 2 - 515
___________________________________________________________________________________
___________________________________________________________________________________
4-11 Ringing Line Preference Selection
General Description
Use this Memory Block to specify whether or not each station user can answer
incoming ringing CO/PBX calls by going off-hook.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NO YS
Programming Procedures
1 Go off-line.
2 Press LK4 +
AA
to access the Memory Block.
3 Press CO/PBX LK1 to prevent the Tel Port No. station user from answering incoming ringing CO/PBX calls by going off hook.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
– OR –
D to go to next assigned Tel Port No.
B +
A
to enter A for Port Numbers 100~109
B +
B
to enter B for Port Numbers 110~119
B +
C
to enter C for Port Number 120
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
4-01
CO/PBX Ring Assignment (Day Mode)
4-02
CO/PBX Ring Assignment (Night Mode)
Telephone Mode
4
Submode
Data No.
11
PC Programming
¦
+BTM
0 1 / 1 1 : R N G P R F Y S
T I M E D I S P L A Y
Tel
Port
No.
(01
~
C0)
Title
Setting
Data
Data
No.