1-1-07 Tie Line Delay Ringing Time
Selection
General Description
Use this Memory Block to specify the time before a Tie line call ringing at a station can
begin ringing at other preassigned stations when it is not answered in a programmed
time. CO/PBX Ringing Assignment defines the preassigned station.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display (R2500 or lower)
Settings
Refer to the next page for R3000 or higher Programming Procedures.
LK 1 LK 2 LK 3 LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
10s 20s 30s
∞
(No Limit)
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 +
KG
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
1
Data No.
07
PC Programming
¦
+ALM
0 7 : T L D L Y R N G
∞
T I M E D I S P L A Y
Setting
Data
Title
Data
No.