2 - 14 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Display (R3000 or higher)
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+
KG
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
000s~255s (e.g., 020s = 20s)
Default Values
Class 1~4 = 000s
000s = No Limit
4 Press G to write the data and display the next Timer Class of Service.
5 Program the next Timer Class of Service or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-34
Tie Line First Ring Pattern Selection
4-01
CO/PBX Ring Assignment (Day Mode)
4-02
CO/PBX Ring Assignment (Night Mode)
4-12
Line Key Selection for Telephone Mode
4-71
Station to Timer Class of Service (R3000 or higher)
0 7 : T L D L Y 1 = 0 0 0 s
T I M E D I S P L A Y
Timer
Class
1~4
Title
Data
No.