Loading...
2 - 6 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-1-03 Hold Recall Time Selection
(Non-Exclusive Hold)
General Description
Use this Memory Block to specify the Hold time for a Non-Exclusive outside call
before a recall tone is generated. When
No Limit is selected, the hold recall alarm tone
is not generated.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display (R2500 or lower)
Settings
Refer to the next page for R3000 or higher Programming Procedures.
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
25s 45s 60s 90s 120s 180s 240s
(No Limit)
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+
KC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
1
Data No.
03
PC Programming
¦
+BM
0 3 : H O L D R E C L 2 5 s
T I M E D I S P L A Y
Title
Data
Setting
Data
No.

Table of Contents