Electra Elite IPK Document Revision 4
Programming Manual A - 7
___________________________________________________________________________________
___________________________________________________________________________________
Tie Line Length of
Delay Signal
Selection
3-22 The time (milliseconds) a delay
pulse is sent to another system.
0 300 4500
Tie Line Incoming
Interdigit Timeout
Selection
3-24 The maximum time an address
signal is missing during
incoming call detection before
an error tone is returned to the
other system.
1s 6s
∞
Tie Line Wink/Delay
Signal Detect
Timeout Selection
3-25 The maximum time for
receiving an acknowledgment
signal from a distant system
before sending a busy tone.
1s 7s
∞
Disconnect
Recognition Time
Selection
3-33 The minimum time (seconds)
before a disconnected circuit
can be accessed again.
00.31.5
Automatic Release
Signal Detection
Selection
3-40 The Signal detection time
(milliseconds) for CO/PBX line
release after a disconnect
signal is received from the
distant CO or PBX.
0 350
∞
DIT/ANA Delay
Answer Time
Selection
3-61* The time an incoming CO/PBX
call rings before changing to a
DIT/ANA call.
0s
00s
(No Time)
0s
00s
60s
99s
*With R3000 or higher, these Memory Blocks have changes in Minimum, Default, or Maximum values
that are indicated by bold figures
Table A-1 Function Time Chart (Continued)
Time
Memory
Block
Definition
Value
Minimum Default Maximum