Loading...
2 - 102 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Display (3000 or higher)
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+
HA
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
01s~99s (e.g., 08s = 8s)
Default Values
04 Seconds
4 Press G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-15-07
K-CCIS Message Response Timeout Assignment
3-91
Trunk Type Selection
3-92
Trunk (Installed, DP/DTMF) Selection
1. When Maximum Digits are assigned, and a user dials a phone number equal to the limit set, the dialed digits are
sent immediately over the Network without waiting for this timer to expire.
2. R3000 or higher is required to adjust this Memory Block by 1-second intervals.
8 1 : I S D N D I A L 0 4 s