2 - 140 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK3 +
KC
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
01s~99s (e.g., 05s =5s)
Default Values
10s
4 Press G to write the data and display the next memory block.
5 Program the next memory block, or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-8-10
PBR Interdigit Release Time Selection
4-95
DTMF/DP SLT Type Selection
R3000 or higher is required to adjust this memory block by 1-second intervals.
0 3 : P B R R L S 1 0 s
T I M E D I S P L A Y
Setting
Data
Data
No.
Title