Electra Elite IPK Document Revision 4
Programming Manual 2 - 273
___________________________________________________________________________________
___________________________________________________________________________________
1-10-05 Call by Call Facility Coding Value
Assignment (Service)
General Description
Use this Memory Block to specify the Facility Coding Value (Service) for each Route
Advance Block (RAB). This setting data is sent in the FCV-S field of the NSF-IE
(Network Specific Facility Code-Information Element) when making outgoing calls.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK10 +
JE
to access the Memory Block. Default Values
All RABs 00 (None)
3 Enter three or four digit data using the dial pad.
Use the following to enter data:
J
and
L
to move the cursor
K
~
I
to enter data
D to select next RAB No.
Setting Data:
System Mode
1
Submode
10
Data No.
05
PC Programming
¦
+AY
0 1 / 0 5 : F C V – S = 0 0
T I M E D I S P L A Y
Data
No.
Setting
Data
RAB
01~32
Title
PRT ETU SW1
Setting Setting Data Description
5ESS (Lucent)
and
4ESS (AT&T)
00 Non-CBC Route Advance Block (None)
01 SDN (Software Defined Network)
02 MEGACOM800
03 MEGACOM
06 ACCUNET (Future)
08 International 800
16 AT&T MultiQuest (900 Service)
NI-2
(Nortel)
17 INWATS
18 OUTWATS
19 Foreign Exchange (FX)
20 Tie Trunk (TIE)
DMS100
(Nortel)
01 Private
02 INWATS
03 OUTWATS
04 Foreign Exchange (FX)
05 Tie Trunk (TIE)