2 - 348 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-15-07 K-CCIS Message Response Timeout
Assignment
General Description
Use this Memory Block to assign the time before a call or message request is
canceled when no response is received from the destination office.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK15 +
KG
to access the Memory Block.
3 Use dial pad keys to enter Setting data.
Use the following to enter data:
Use
J
to move cursor left
Use
L
to move cursor right
Use
K
~
I
to enter numeric data
Setting Data:
00 =
(Infinity)
01~99 Seconds are valid times.
Default Values
:
30 Seconds
4 Press G to write the data.
5 Press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1
Card Interface Slot Assignment
7-3-01
MIF (LCR) Assignment
7-3-02
MIF (SMDR) Assignment
1-15-00
K-CCIS Main/Remote Office Selection
1-15-01
Common Signal Channel Data Speed Assignment
1-15-02
Common Signal Channel Assignment
1-15-03
Originating Point Code Assignment
1-15-04
Destination Point Code Assignment
System Mode
1
Submode
15
Data No.
07
PC Programming
¦
+AW
0 7 : R E S T I M E 3 0 s
T I M E D I S P L A Y
Setting
Data
Data
No.
Title

Table of Contents