2 - 366 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-15-16 Centralized BLF Send Extension
Number Assignment
General Description
Use this Memory Block to assign the Extension Numbers for sending Centralized BLF
messages.
R1500 or higher is required.
Display
Settings
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
Send Group
1
Send Group
2
Send Group
3
Send Group
4
Send Group
5
Send Group
6
Send Group
7
Send Group
8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK15 +
AF
to access the Memory Block.
3 Use dial pad keys to enter Table number and Extension No.
Use the following to enter data:
J
to move cursor left
L
to move cursor right
K
~
I
to enter numeric data
Three Digit Extension Number: 100~899
Four Digit Extension Number: 1000~8999
Tables 001~120 can be assigned.
Default Values
:
All Tables Not Specified
4 Press corresponding CO/PBX line key to select the Send Group No.
5 Press
G to write the data, and display the next Memory Block.
6 Repeat Steps 4 and 5 for each Send Group No.
7 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
15
Data No.
16
PC Programming
¦
+AW
1 5 : S E N D 0 0 1 =
T I M E D I S P L A Y
Data
No.
Table
No.
(001~120
Title
Extension
Number

Table of Contents