Electra Elite IPK Document Revision 4
Programming Manual 2 - 377
___________________________________________________________________________________
___________________________________________________________________________________
Notes
1. When no outgoing trunks are available at the main or tandem office, and a 911 call is originated at the remote
office, the following alternate outgoing process is applied when this Memory Block is set to YS (allow):
When a trunk number is assigned in Memory Block 1-8-43, and a Centralized 911 call is originated, the Electra
Elite IPK searches for an idle trunk in the Trunk Group (TG)/Route Advance Block (RAB) assigned in Memory
Block 1-8-44.
When an RAB is assigned in Memory Block 1-8-43, and a Centralized 911 call is originated, the Electra Elite IPK
searches for an idle line in the TG that has lower priority in the route advance block assigned in Memory Block
1-8-43, and then searches for an idle line in the trunk group/route advance block assigned in Memory Block
1-8-44.
When a Centralized E911call is originated by an RAB assigned by Memory Block 1-8-44, the Electra Elite IPK
searches for an idle line in the Trunk Group with lower priority than the RAB assigned in Memory Block 1-8-44.
When a Centralized E911 call is originated by a TG assigned in Memory Block 1-8-44 or an idle line cannot be
found in the outgoing line search process, the caller hears a busy tone with BUSY display.