Electra Elite IPK Document Revision 4
Programming Manual 2 - 483
___________________________________________________________________________________
___________________________________________________________________________________
Display (3000 or higher)
Notes
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
FA
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
00s~99s (e.g., 02s = 2s)
Default Values
00s
00s = No Time
4 Press G to write the data and display the next memory block.
5 Program the next memory block, or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
3-42
DIT Assignment
3-43
ANA Assignment
3-62
DIT Tenant Assignment
1. When the time is set to a value other than 0, call termination is treated as a normal incoming call and DIT
termination is performed after the time elapses. When 0 is selected, DIT call termination is performed
immediately.
2. R3000 or higher is required to adjust this memory block by 1-second intervals.
0 1 / 6 1 : D L Y A N S 0 0 s
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Setting
Data
Title