2 - 10 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+
KE
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
00s~99s (e.g., 02s = 2s)
Default Values
Class 1~4 = 02s
00s = No Limit
4 Press G to write the data and display the next Timer Class of Service.
5 Program the next Timer Class of Service or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-5-25
SMDR Valid Call Time Assignment
4-71
Station to Timer Class of Service (R3000 or higher)
1. This time is used for the features with functions described below:
Elapsed Call Time: The time after dialing before the Elapsed Call Time is started and displayed on a Multiline
Terminal.
SMDR Start Time: The time needed after dialing before the SMDR Valid Call Time is started. Refer to Memory
Block 1-5-25 (SMDR Valid Call Time Assignment). For outgoing calls, both Elapsed Call Time and SMDR Valid
Call Time must elapse before a call record is generated.
2. Telephone ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station
to Timer Class of Service, Class 2 by default (R3000 or higher)
.
3. When a system is upgraded from R2500 or lower, the Start Time Selection is reset to the default value during
the upgrade process (R3000 or higher)
.
4. For copper trunks only. Not supported on digital trunks.