Planet SGS-6341-24T4X - Ethernet - Oam Errored - Symbol - Period Threshold High

Planet SGS-6341-24T4X
1206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11-31
Usage Guide:
Detect errored frame seconds of the port after the time of specific detection period. If the number of
errored frame seconds is larger than or equal to the threshold, corresponding event is induced and
the device notified the peer through OAMPDU.
Example:
Configure the detection period of errored frame seconds event on port 1/0/4 to 120s.
Switch(Config-If-Ethernet1/0/4)#ethernet-oam errored-frame-seconds window 120
11.16 ethernet-oam errored-symbol-period threshold
high
Command:
ethernet-oam errored-symbol-period threshold high {<high-symbols> | none}
no ethernet-oam errored-symbol-period threshold high
Function:
Configure the high threshold of errored symbol event, no command restores the default value.
Parameter:
<high-symbols>, the high detection threshold of errored symbol event, ranging from 2 to
18446744073709551615 symbols.
none, cancel the high threshold configuration.
Default:
None.
Command Mode:
Port mode
Usage Guide:
During the specific detection period, serious link event is induced if the number of errored symbols
is larger than or equal to the high threshold and the device notifies the peer by sending Information
OAMPDU of which the value of Link Fault flag in Flags field is 1. Note that the high threshold should
not be less than the low threshold.
Example:
Set the high threshold of errored symbol event on port 1/0/4 to none.
Switch(Config-If-Ethernet1/0/4)#ethernet-oam errored-symbol-period threshold high none