EasyManuals Logo

Planet SGS-6341-24T4X User Manual

Planet SGS-6341-24T4X
1206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
SGS-6341 Series Command Guide
4-139
Parameters:
auto is the auto speed and duplex negotiation, 10 is 10Mbps speed, 100 is 100Mbps speed, 1000 is 1000Mbps
speed, auto is duplex negotiation, full is full-duplex, half is half-duplex; force10-half is the forced 10Mbps at
half-duplex mode; force10-full is the forced 10Mbps at full-duplex mode; force100-half is the forced 100Mbps at
half-duplex mode; force100-full is the forced 100Mbps at full-duplex mode; force100-fx is the forced 100Mbps at
full-duplex mode; module-type is the type of 100Base-FX module; auto-detected: automatic detection;
no-phy-integrated: there is no phy-integratd 100Base-FX module; phy-integrated: phy-integratd 100Base-FX
module; force1g-half is the forced 1000Mbps speed at half-duplex mode; force1g-full is the forced 1000Mbps
speed at full-duplex mode; nonegotiate disables auto-negotiation forcibly for 1000Mb port; master forces the
1000Mb port to be master mode; slave forces the 1000Mb port to be slave mode. force10g-full is the forced
10000Mbps speed at full-duplex mode.
Command mode:
Port Mode.
Default:
Auto-negotiation for speed and duplex mode is set by default.
Usage Guide:
This command is configures the port speed and duplex mode. When configuring port speed and duplex mode, the
speed and duplex mode must be the same as the setting of the remote end, i.e., if the remote device is set to
auto-negotiation, then auto-negotiation should be set at the local port. If the remote end is in forced mode, the same
should be set in the local end.
1000Gb ports are by default master when configuring nonegotiate mode. If one end is set to master mode, the other
end must be set to slave mode.
force1g-half is not supported yet.
Example:
Port 1 of SwitchA is connected to port 1 of SwitchB, the following will set both ports in forced 100Mbps at half-duplex
mode.
SwitchA(config)#interface ethernet1/0/1
SwitchA(Config-If-Ethernet1/0/1)#speed-duplex force100-half
SwitchB(config)#interface ethernet1/0/1
SwitchB(Config-If-Ethernet1/0/1)#speed-duplex force100-half
4.1.17 virtual-cable-test
Command:
virtual-cable-test

Table of Contents

Other manuals for Planet SGS-6341-24T4X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planet SGS-6341-24T4X and is the answer not in the manual?

Planet SGS-6341-24T4X Specifications

General IconGeneral
Switch typeManaged
Switch layerL3
Quality of Service (QoS) supportYes
Form factor1U
CertificationFCC Part 15 Class A, CE
Product colorBlack
Console portRJ-45
SFP+ module slots quantity4
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity24
Routing entries128
Networking standardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3ae, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Virtual LAN featuresStacked VLAN, Private VLAN, Tagged VLAN, Protocol-based VLAN
Copper ethernet cabling technology10BASE-T, 100BASE-T, 1000BASE-T
Flash memory16 MB
Internal memory512 MB
Processor frequency400 MHz
AuthenticationMAC-based authentication, Port-based authentication
Security algorithmsSNMPv3, SSH, SSL/TLS
Throughput95.24 Mpps
Jumbo frames9216
Number of queues8
MAC address table16000 entries
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power supply included-
Power consumption (max)19.9 W
Heat dissipation67.91 BTU/h
Storage temperature (T-T)-10 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 90 %
Harmonized System (HS) code85176990
Weight and Dimensions IconWeight and Dimensions
Depth240 mm
Width440 mm
Height43.6 mm
Weight3170 g

Related product manuals