8-86 Phaser 6300/6350/6360 Color Laser Printer Service Manual
Service Parts Disassembly
Toner Cartridge Holder (PL7.2.1~4)
The procedure for removal of the Toner Cartridge Holder is the same for all
colors.
o
e
To control Toner spillage, do not disconnect the Auger Tube from the
Developer Frame Assembly unless absolutely necessary to perform the
repair. Remove the HVPS to access the Auger Tube connections.
1. Remove the CRUM Reader (page 8-84).
o
e
With the CRUM Reader removed, any of the four Toner Cartridge Holders
are available for removal and servicing.
2. Disconnect the appropriate Toner Motor and No Toner Sensor
connections from the holder being removed.
3. Remove the harness from the clamp mounted directly above the motor.
4. Remove the screw (metal, 6 mm) that secures the end of the Toner
Cartridge Holder to the Toner Cartridge Holder Assembly.
5. Release the T-shaped hook near the Toner Motor to release the Toner
Cartridge Holder from the assembly.
6. Disconnect the Auger Tube.