100 Upgrade and Maintenance Manual
RX100 S7
Basic software procedures
I For detailed information on iRMC settings, refer to the "iRMC S2/S3 -
integrated Remote Management Controller" user guide.
Executing the fan test via ServerView Operations Manager
Ê Open the ServerView Operations Manager and log in.
Ê Under Administration select Server Configuration.
Ê In the hierarchy tree of the Server list tab, select the server to be configured.
Ê In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO....
In the left-hand section of the window, the Configuration tab is being
activated.
Ê In the navigation area of the Configuration tab, select Other Settings.
Ê Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
Ê Click Save Page.
The fan test will be started at the specified time.
Ê After the fan test is complete, restore the time setting to its initial value and
click Save Page.
I For more detailed information, refer to the "ServerView Operations
Manager" user guide.
For the Japanese market: Executing the fan test via Chassis ID Prom Tool
Ê Prepare a boot medium (CD) containing the Chassis ID Prom Tool.
Ê Insert the CD into the DVD drive and close the drive tray.
Ê Shut down and restart the server.
The server will boot from the Chassis ID Prom Tool medium.
Ê After the boot process is complete, press [ESC] to enter the command
prompt screen.
Ê Enter IPMIVIEW.EXE and press [Enter] to start the IPMI Tool.
Ê Under System Specific Functions select Fan Test and press the [F9] function
key to start the fan test.