56 Upgrade and Maintenance Manual
 RX100 S7
Basic hardware procedures
I For further information, refer to the "ServerView Suite Local Service 
Concept (LSC)" manual available from the ServerView Suite DVD 2 
supplied with your PRIMERGY server or online at 
http://manuals.ts.fujitsu.com (EMEA market) or 
http://jp.fujitsu.com/platform/server/primergy/manual/ (Japanese 
market).
Ê When using ServerView Operations Manager to toggle the ID indicator, 
choose Single System View and press the Locate button.
Ê Remember to switch off the ID indicator after the maintenance task has been 
concluded successfully.
4.1.2 Determining the error class
The Local Service Concept (LSC) allows you to identify defective server 
components. Failure events are assigned to one of two error classes:
– Global Error events that need to be resolved by maintenance personnel
– Customer Self Service (CSS) error events that may be resolved by 
operating personnel
Global Error and CSS LEDs indicate, if the defective component is a customer 
replaceable unit or if maintenance personnel needs to be dispatched to replace 
the part.
I The indicators also light up in standby mode and after a server restart 
due to a power failure.
4.1.2.1 Global Error indicator
Ê Check the Global Error indicator on the front or connector panel of the server 
(see section "Connectors and indicators" on page 447).