EasyManua.ls Logo

Fujitsu PRIMERGY RX100 S7 - Removing a 3.5-Inch HDD Module; Preliminary Steps; Required Tools

Fujitsu PRIMERGY RX100 S7
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX100 S7
Upgrade and Maintenance Manual 163
Hard disk drives / solid state drives
7.2.3 Removing a 3.5-inch HDD module
V CAUTION!
Follow the safety instructions in chapter "Important information" on
page 43.
V Only applicable for removing non-defective HDD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD module that is not
defective.
7.2.3.1 Required tools
Preliminary and concluding steps: tool-less
Main steps: tool-less
7.2.3.2 Preliminary steps
Ê Perform the following procedures:
1. Ensure that the HDD module to be removed is not combined into a RAID
array. If the drive is part of a RAID array, you first need to delete the array
using ServerView RAID Manager.
V CAUTION!
All data on all HDDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
I For further information, please refer to the "ServerView Suite
RAID Management" user guide, available online at
http://manuals.ts.fujitsu.com (EMEA market) or
http://jp.fujitsu.com/platform/server/primergy/manual/ (Japanese
market) or from the ServerView Suite DVD 2 supplied with your
PRIMERGY server.
2. "Opening the rack door" on page 59
Customer Replaceable Units (CRU)
Average task duration: 5 minutes

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S7

Related product manuals