308 Upgrade and Maintenance Manual
RX100 S7
Optical disk drive
12.4.1 Required tools
Preliminary and concluding steps: tool-less
Main steps: Phillips PH0 / (+) No. 0 screw driver
12.4.2 Preliminary steps
Ê Perform the following procedures:
1. "Opening the rack door" on page 59
2. "Locating the defective server" on page 55
3. "Removing backup and optical disk media" on page 77
4. "Disabling BitLocker functionality" on page 75
5. "Shutting down the server" on page 59
6. "Extending/removing the server from the rack" on page 60
7. "Opening the server" on page 64
12.4.3 Disconnecting the cables from the defective ODD
Ê Disconnect the cables from the ODD as described in section "Disconnecting
the cables from the ODD" on page 303.
12.4.4 Removing the defective ODD
Ê Remove the ODD as described in section "Removing the ODD" on
page 304.
12.4.5 Removing the retaining spring from the defective
ODD
Ê Remove the retaining spring as described in section "Removing the retaining
spring from the ODD" on page 304.