RX100 S7
Upgrade and Maintenance Manual 165
Hard disk drives / solid state drives
7.2.3.4 Installing the 3.5-inch dummy module
Figure 80: Installing the 3.5-inch dummy module
Ê Push the dummy module into the empty bay until it engages.
7.2.3.5 Concluding steps
Ê Perform the following procedures:
1. "Closing the rack door" on page 73
7.2.4 Replacing a 3.5-inch HDD module
V CAUTION!
●
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "PRIMERGY RX100 S7 Server -
Operating Manual".
●
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
Customer Replaceable Units (CRU)
Average task duration: 5 minutes