RX100 S7
Upgrade and Maintenance Manual 87
Basic software procedures
Re-enabling backup drives
If a backup drive has been disabled or deleted from the backup software drive 
list as described in section 5.1.4 on page 78, it has to be re-enabled to complete 
the maintenance task.
Ê Re-enable backup drives and revise backup software settings and cronjobs.
I Detailed information on suitable backup software solutions and 
related documentation is available to Fujitsu service partners from the 
Fujitsu Extranet pages
5.2.6 Resetting the boot retry counter
The boot retry counter is decremented from its preset value every time the 
POST watchdog initiates a system reboot. When the value has reached ’0’, the 
system will shut down and power off.
5.2.6.1 Viewing the boot retry counter
The current boot retry counter status is available in the BIOS:
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under Boot Retry Counter the current number of remaining boot attempts is 
displayed. The value is further decremented with every failed boot attempt 
or system reboot resulting from critical system errors.
Ê Exit the BIOS.
5.2.6.2 Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every 
service task.
I Please note, if the customer does not know about the original boot 
retry values:
If the system boots up and no further errors occur within 6 hours after that 
successful boot attempt, the boot retry counter will automatically be reset 
to its default value. Please take into account, that the specified number 
of boot attempts can only be determined after this period of time.