EasyManua.ls Logo

Fujitsu PRIMERGY RX100 S7 - Inch HDD;SSD Subsystem; 7 Hard Disk Drives; Solid State Drives; Equipping the 2.5-Inch HDD;SSD Bays

Fujitsu PRIMERGY RX100 S7
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX100 S7
Upgrade and Maintenance Manual 145
Hard disk drives / solid state drives
7.1 2.5-inch HDD/SSD subsystem
7.1.1 Equipping the 2.5-inch HDD/SSD bays
Figure 65: Equipping the 2.5-inch HDD/SSD bays
Solid state drives (SSDs) are always equipped before installing hard disk
drives.
If only one HDD/SSD module is installed, the HDD/SSD module will be
installed in position 1. Free bays must be equipped with a dummy module.
Installing different capacities, install the biggest capacity first.
Installing different rotating speed, install the fastest rotating speed first.
SAS connectivity
HDD/SSD naming scheme
I The HDD/SSD numbering as listed in the ServerView RAID Manager
differs from the HDD mounting order:
Controller Channel Connection
SAS controller
in slot 1
1 Drives 1, 2, 3, 4
2.5-inch HDDs/SSDs
Bay
RAID
Manager
#
Channel
log.
Drive #
Bay
RAID
Manager
#
Channel
log.
Drive #
1 [0] 102[1] 20
3 [2] 114[3] 21
Table 5: HDD naming scheme
/ 0