17.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê Shut down the server as described in section "Shutting down the server" on
page 59.
Ê Remove the AC power cord from the cable tie or cable clamp and disconnect
it from the system.
Ê Take the system down to its minimum startup configuration.
Ê Reconnect the AC power cord to the power supply unit and secure it with a
cable tie or cable clamp.
Ê Connect a keyboard, mouse and display to the server.
Field Replaceable Units (FRU)
Component Notes
System board no TPM, UFM or expansion cards installed
CPU with CPU heat sink
1 memory module installed in DIMM slot 1A
Front panel module
Power supply unit
Table 8: Minimum startup configuration - components
Cable Notes
Front panel cable
Power cable
Table 9: Minimum startup configuration - cables