EasyManua.ls Logo

Fujitsu PRIMERGY RX100 S7 - Disconnecting the Cables; Removing the Defective 2.5-Inch SAS;SATA Backplane

Fujitsu PRIMERGY RX100 S7
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
156 Upgrade and Maintenance Manual
RX100 S7
Hard disk drives / solid state drives
7.1.5.3 Disconnecting the cables
Figure 71: Disconnecting the cables from the 2.5-inch SAS/SATA backplane
Ê Disconnect the following cables from the SAS/SATA backplane:
(1) power cable from connector J4
(2) SGPIO cable from connector J2
(3)-(6) SAS/SATA data cables from connectors SATA1, SATA2, SATA3,
SATA4
For the cable plan see section "Cabling" on page 462.
7.1.5.4 Removing the defective 2.5-inch SAS/SATA backplane
Figure 72: Removing the 2.5-inch SAS/SATA backplane
Ê Pull the SAS/SATA backplane upward until the bolts disengage (see circles).
Ê Take out the SAS/SATA backplane.
1
2
0
3
4 5

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S7

Related product manuals