Basic software procedures
5.2 Completing the maintenance task
5.2.1 Updating the system board BIOS and iRMC
After replacing the system board, it is essential to upgrade the BIOS to the latest
version.
The latest BIOS and iRMC versions are available from the Fujitsu support
internet pages at:
http://ts.fujitsu.com/support/ (EMEA market)
http://jp.fujitsu.com/platform/server/primergy/downloads/ (Japanese market)
I Fujitsu does not assume responsibility for any damage done to the
server or for the loss of any data resulting from BIOS updates.
BIOS recovery procedure
I For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick with the following files:
Update tool
Startup.nsh (which will execute the update tool)
BIOS image file for update (16 MB with header information)
Ê Shut down the server as described in section "Shutting down the server" on
page 59 and disconnect it from the mains.
Ê Remove the top cover as described in section "Opening the server" on
page 64.
Ê Enter BIOS recovery mode using the onboard jumpers.
I For detailed information on jumper settings, refer to section "Jumper"
on page 459 or the "System Board D3034 Technical Manual".
Ê Close the top cover as described in section "Closing the server" on page 66.
Ê Connect the USB stick to the USB connector.
Ê Connect the server to the mains.