82 Upgrade and Maintenance Manual
RX100 S7
Basic software procedures
Ê Press the On / Off button to start up the server.
The system will detect the USB stick and the BIOS recovery process will be
performed.
V CAUTION!
Do not interrupt the BIOS upgrade process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê After completion of the flash process, shut down the server.
Ê Remove the top cover as described in section "Opening the server" on
page 64.
Ê Disable BIOS recovery mode using the onboard jumpers:
I For detailed information on jumper settings, refer to section "Jumper"
on page 459 or the "System Board D3034 Technical Manual".
Ê Close the top cover as described in section "Closing the server" on page 66.
iRMC recovery procedure
I For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable iRMC firmware update image.
Ê Shut down the server as described in section "Shutting down the server" on
page 59 and disconnect it from the mains.
Ê Connect the USB stick to the USB connector.
I Ensure that only the USB device with the iRMC firmware is connected
to the USB connector. Remove all other USB devices temporarily.
Ê Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
Ê Press the Power On / Off button. The system starts the POST process.
I In iRMC reocovery mode, the “FUJITSU” logo does not show up.