RX100 S7
Upgrade and Maintenance Manual 377
System board and components
Ê Perform the following procedures:
1. "Opening the rack door" on page 59
2. "Locating the defective server" on page 55
3. If applicable, ensure to note down your current network settings in the
operating system.
4. "Disabling SVOM boot watchdog functionality" on page 76
5. "Disabling BitLocker functionality" on page 75
6. "Shutting down the server" on page 59
7. Disconnect all external cables.
8. "Extending/removing the server from the rack" on page 60
9. "Opening the server" on page 64
10.Remove all memory modules, see section "Removing a memory
module" on page 275.
I Before removing the memory modules, take a note on the
installation slot number for each memory module. Make sure that
you reinstall the memory modules in the slot they were located
before the replacement.
11. Remove the air duct, see section "Removing the air duct" on page 282.
12.Remove the heat sink, see section "Removing the heat sink" on
page 283.
13.Remove all expansion cards, see section "Expansion cards and riser
modules" on page 199.
I Before removing the expansion cards, take a note on the
installation slot number for each card. Make sure that you reinstall
the card in the slot it was located before the replacement.
14.Remove the front LAN card (if applicable), see section "Removing the
defective front LAN card" on page 343.
15.Remove the UFM (if applicable), see section "Removing the defective
UFM" on page 359.
I Remove the UFM spacer from the defective system board and
fasten it with the UFM screw to the UFM board.