450 Upgrade and Maintenance Manual
RX100 S7
Appendix
The LEDs have the following meaning:
LED Indicator Meaning
A - CSS
(Customer Self
Service)
off no error (CSS component)
yellow on indicates a prefailure (CSS component)
yellow flashing indicates a failure (CSS component)
B - GEL
(Global Error
LED)
off no error (non CSS component)
orange on indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
over temperature measured by one of
the sensors
sensor is defective
CPU error
software detected an error
C - Identification blue on server is identified via the ServerView
Operations Manager
blue flashing local monitor off
D - Memory off memory module running
orange on memory module failure
E - CPU off CPU okay
orange on CPU failure
F - System fan off fan running
orange on fan failure
G - PCI card off PCI card okay
orange on PCI card failure (PCI card installed on riser
card)
H - iRMC off iRMC S3 inactive
green flashing iRMC S3 okay