358 Matrix ETERNITY NE System Manual
• Select the radio button Manual Cell Locking of that Cell.
• Click Submit button.
• The BCCH Locking for the selected Mobile Port will appear on this page, if Auto Refresh is enabled.
• If you have stopped Auto Refresh, click Refresh at the bottom of the page to refresh the page and view the
current BCCH Locking settings of the selected Mobile port.
• You may now log out of Jeeves.
Example:
Consider the following example when using this feature:
Problem:
• ETERNITY is installed in roaming area, where more than one network is available, network A and network
B.
• Mobile Network Selection is set to 'Manual' mode, network A is selected as the first priority and network B
is selected as the second priority.
• The Mobile Port gets registered with network A. After registration, the user locks the Mobile Port to one of
the cells of network A.
• After registration, if the module or the system restarts or gets de-registered from the network, module
starts registration process again.
• While re-registering, ETERNITY tries to lock the Mobile Port to the last selected cell of network A.