Matrix ETERNITY NE System Manual 781
In this protocol, the ETX is at the column position 61; hence the ETERNITY will send blanks from column position
50 to 60.
XIOX:
Location 00 NA NA NA --
Trunk Number 00 NA NA NA --
Units 00 NA NA NA --
Account Code 00 NA NA NA --
Prefix String
(ac01)
00 NA NA NA --
Remarks 00 NA NA NA --
Field
Start Column
Number
Field
Length
Alignment
Filler
Character
Remarks
Serial Number 01 03 RA Zero The Serial number wraps to 001
every midnight.
Increment
Counter
04 01 NA NA This field is initialized to B. This field
can be programmed to any other
value. However, we shall not give this
programmable within the XIOX
protocol itself. If it is required by the
customer to start his field from say
'C', he shall have to use customized
option.
Property Code 06 03 NA NA As per the Programmed String
Date 10 05 NA Zero MM/DD
Station Number 16 04 LA Space Whether this field is of four digits or
five digits is not documented. Hence,
it is assumed to be of four digits.
Time 21 05 NA Zero HH:MM
Duration 27 04 NA NA Duration is in Minutes. What happens
to bigger duration call is now known.
We can assume roll over.
Currency Symbol 32 01 NA NA $
Amount 33 06 RA Zero Format is DDD.CC
Called Number 40 08 RA Space Exchange code and Subscriber
Number separated by dash. No Area
code is sent
Field Start Column
Number
Field
Length
Alignment Filler
Character
Remarks