46 Matrix ETERNITY NE System Manual
Technical Specification of the DOP
Also refer the topic “Digital Output Port (DOP)”.
1. Make sure that the power supply is switched off, before you begin connecting the door phone.
2. Now, plug in the cable supplied with the card into the Door Phone connector. Terminate the free end of the
cables into the main distribution frame.
Refer to the pinout details of the Door Phone port to connect the wires correctly.
Pinout and Cable Details of Door Phone Port
3. The wires of the devices, the Door Phone and the Door Lock, which you want to connect to the ETERNITY
NE, should be terminated in to the Distribution Frame. Refer the pinout details of the ports to connect the
cables.
Connecting Door Phone
You can connect any standard 4-wire door phone. Refer to the pin out details given above to make the
connections.
Make sure that the door phone you connect conforms with the Technical Specifications of the door
phone port.
Connecting a Door Lock Release Device
If a Door Lock is to be used in conjunction with the Door Phone, connect the Door Lock to the Digital
Output Port (DOP) of the ETERNITY NE.
Specification Value
Relay Type Power Relay
Contact Arrangement Normally Open; 1-Form-A
Contact Rating(Resistive Load) 1.5Amp; 120VAC/150VDC
Operation Time: 8ms (max.)
Connector Pin Port Connection Colour
RJ45
1
DOP-1
Relay A Orange-White
2 Relay B Orange
3
Door Phone-1
Status Green-White
4 MIC Input Blue
5 Speaker Output Blue-White
6 Analog Ground Green
7
8