808 Matrix ETERNITY NE System Manual
To generate Fault logs from an extension phone,
Enter SA mode from a DKP/SLT/Extended IP Phone.
To start/stop Online fault log generation:
•Dial 1072-028-1 to start
•Dial 1072-028-0 to stop
To start/stop offline Report generation:
•Dial 1072-027-1 to start
•Dial 1072-027-0 to stop
To clear Fault Logs,
•Dial
Exit SA mode.
You may print the logs captured on the Syslog Server after suitable modification of the format.
The format of the standard system fault report looks as below:
The Online log would look like this:
16-02-2011 16:51:41 DKP Absent : 301 , Slot=01, Port=01
The Offline Report would look like this:
SYSTEM FAULT LOG AS ON 16-02-2011(Wed) AT 16:17
-------------------------------------------------------------------------------
16-02-2011 16:14:39 DKP Absent : 302 , Slot=01, Port=02
-------------------------------------------------------------------------------
Eternity V10R04 Page : 1
Field Column Position
Blank 00
Date (As per Date format selected) 01
Time (HH:MM:SS) 12
Even Index No. (two characters) 21
Event Description 24