2 - 314 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-13-05 PRT B Channel-to-Trunk Group
Assignment
General Description
Use this Memory Block to assign a Trunk Group Number to each B channel or any
Trunk Group for each B channel. Changing this assignment is not normally required
and default should be set. This Memory Block could be used when different trunks are
used in the same PRI span or for a tenant application where multiple tenants share the
PRI span and separation of B channels is required.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK13 +
KE
to access the Memory Block.
3 Use dial pad keys to enter Trunk Group.
Use the following to enter data:
J
to move cursor left
L
to move cursor right
K
~
I
to enter numeric data
00 is No Trunk Group
01~32 are Trunk Groups 01~32
Default Values
00, No Trunk Group
4 Press G to write the data and display the next B channel or next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
13
Data No.
05
PC Programming
¦
+AN
0 1 / 0 5 : B 0 1 = T G 0 O
T I M E D I S P L A Y
Data
No.
Setting Data
Trunk Group
PRT
1~8
B Ch.
01~23

Table of Contents