EasyManua.ls Logo

Planet SGS-6341-24T4X - Page 1117

Planet SGS-6341-24T4X
1206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67-2
Do not configure
Usage Guide:
Configure this command when using sFlowTrend.
Example:
Switch(config)#sflow analyzer sflowtrend
67.3 sflow counter-interval
Command:
sflow counter-interval <interval-value>
no sflow counter-interval
Function:
Configure the max interval of the sFlow statistic sampling; the “no” form of this command deletes
the statistic sampling interval value.
Parameter:
<interval-value> is the value of the interval with a valid range of 20~120 and shown in second.
Command Mode:
Port Mode
Default:
No default value
Usage Guide:
If no statistic sampling interval is configured, there will not be any statistic sampling on the interface.
Example:
Set the statistic sampling interval on the interface e1/0/1 to 20 seconds.
Example:
Switch(Config-If-Ethernet1/0/1)#sflow counter-interval 20
67.4 sflow data-len
Command:
sflow data-len <length-value>
no sflow data-len
Function:
Configure the max length of the sFlow packet data; the “no sflow data-len” command restores the
default value.