6 FUNCTIONS OF THE OPERATION SCREENS CCW-R-2**B INSTRUCTION MANUAL
6-76
6.11.6 [Weight Setting] Index Screen
To display the [Weight Setting] index screen ([Preset] screen), press the [Weight Setting] index on the
[Preset] screen.
Fig.6-81 [Weight Setting] Index Screen ([Preset] Screen)
Table 6-31 Items and Functions of the [Weight Setting] Index Screen
No. Name Function
1 [Extended Upper Limit] key Aiming at efficiency improvement, sets the tolerance for a certain proper
weight from the [Numeric Keypad] screen so that products can be discharged
as proper weight even if the upper limit is exceeded once in a specified number
of proper weight dumps.
The key is unavailable when the upper weight limit is 0.0g.
2 [Upper Weight Limit] key Sets the upper limit of proper weight from the [Numeric Keypad] screen.
3 [Target Weight] key Sets the target weight from the [Numeric Keypad] screen.
4 [Lower Weight Limit] key Sets the lower limit of proper weight from the [Numeric Keypad] screen.
This key is unavailable while the average control is set to [Off].
5 [Extended Upper Limit Dump Cycle]
key
Sets the upper limit of the number of cycles of proper discharge with the
tolerance set for the extended upper limit (Item No.1).