9 CLEANUP PROCEDURES CCW-R-2**B INSTRUCTION MANUAL
9-8
9.4.1.1 Inlet Chute
1. Loosen the butterfly nut to remove the inlet
chute.
2. After washing and sterilizing, dry. (For the
washing and sterilization methods, refer to
“Table 9-3 Washing and Sterilization Methods
of Inlet Chute”)
3. Reinstall in the reverse order of the removal.
4. Make sure the inlet chute is installed securely.
Fig.9-4 Inlet Chute
Table 9-3 Washing and Sterilization Methods of Inlet Chute
Washing method Immersion cleaning (Neutral detergent)
Sterilization method Immersion sterilization.
Warm water (80 to 90 deg C): 30 minutes.
Or,
sodium hypochlorite (available chlorine concentration 250 ppm): 20 minutes.
Inlet chute