CCW-R-2**B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS
6-73
6.11.4 [Feeder Adjustment] Index Screen
To display the [Feeder Adjustment] index screen, press the [Feeder Adjustment] index on the [Preset]
screen.
• Refer to “6.13 [Feeder Adjustment] Screen” for feeder adjustment procedures. For feeder
adjustment from the [Production] screen, refer to “6.13 [Feeder Adjustment] Screen”.
Fig.6-79 [Feeder Adjustment] Index Screen ([Preset] Screen)
Table 6-29 Items and Functions of [Feeder Adjustment] Index Screen
No. Name Function
1 [Time] key ON: Enables adjustment of radial feeder operation time.
2 [AMP] key ON: Enables adjustment of radial feeder amplitude.
3 [Target Wt] key Appears if DF is selected. Sets the optimum weight for the dispersion table.
4 [Read Default] key Calls the feeder default value.
5 [Read OptimumVal] key Calls the feeder optimum value.
Available only when the feeder optimum value is registered in the
[Production] screen. ( 6.7 [Production] Screen)