12 INSTALLATION CCW-R-2**B INSTRUCTION MANUAL
12-24
12.5.5 Span Adjustment
For the span adjustment, follow the procedures below.
1. Place the span adjustment weight on all of the
weigh hoppers.
• Normally the span adjustment weight is
200g. However, it may vary depending
on the specifications.
Fig.12-28 Weigh Hopper
2. Press the [ALL Head SLCT/CLR] key
.
X All heads are selected.
Fig.12-29 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)
3. Press the [WH Span Adjustment] key .
X The span adjustment starts.
Fig.12-30 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)