Page #397 background image
CCW-R-2**B INSTRUCTION MANUAL 12 INSTALLATION
12-23
5. Press the [Zero Adjst] key .
X The hopper opens/closes, and along with the
message “Please wait a moment,” the zero
adjustment starts.
Fig.12-26 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)
6. After the zero adjustment is complete, check
that the weight display of each weigh head is
within 0.0g±0.1g.
If the weight display of each head
exceeds 0.1g or falls below -0.1g,
repeat the procedure from step 3.
The operation details of the zero
adjustment procedures
( 6.6 [Zero Adjustment] Screen)
Then, perform the span adjustment.
(See the following.)
Fig.12-27 [Weighing Adjst] Tab Screen