CCW-R-2**B INSTRUCTION MANUAL 11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES
11-17
11.3 Failure and Malfunction of the Weighing
Machine
When the weighing machine fails but no error message is displayed, perform the correcting action by
referring to “Table 11-10 Failure and Malfunction List”.
Table 11-10 Failure and Malfunction List
Status Cause Action
The main power breaker shuts
down.
Electric leakage of the weighing
machine.
Contact the distributor or Ishida customer
support.
Table 11-12
Short circuit in the electrical circuit of
the weighing machine.
The products are discharged at a
timing other than the discharging.
Foreign matter or product is caught in
the pool hopper, weigh hopper or
timing hopper.
Remove the obstruction.
Nothing is displayed on the screen
of the remote control unit.
The main switch is not turned on. Turn on the main switch.
(Customer’s equipment)
Power switch is turned OFF. Turn ON the breaker.
(PS-0 unit)
Turn ON the circuit protector of the PS-0
unit.
Breaking or poor connection. Contact the distributor or Ishida customer
support.
Table 11-12
Chattering when turning on the power. Turn OFF the power and turn ON again.
Display malfunction. Contact the distributor or Ishida customer
support.
Table 11-12
The weigher does not operate when
the power of the remote control unit
is turned ON.
RCU board malfunction. Contact the distributor or Ishida customer
support.
Table 11-12
The interlock signal is not input.
Interlock between the relay units.
LED for switch monitor does not blink
(abnormal).
Turn on the packer.
Make sure that the interlock signal cable is
not broken.
(Is the interlock signal DC24V input to the
external connection terminal?)
Table 11-12
The interlock signal is not input.
Interlock between the relay units.
LED for switch monitor blinks
(normal).
Contact the distributor or Ishida customer
support.
Table 11-12
FDC board malfunction.
The hourglass continues to rotate and
the [Power] key cannot be set to ON.
Contact the distributor or Ishida customer
support.
Table 11-12

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA CCW-R-2 B Series and is the answer not in the manual?

ISHIDA CCW-R-2 B Series Specifications

General IconGeneral
BrandISHIDA
ModelCCW-R-2 B Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals