12 INSTALLATION CCW-R-2**B INSTRUCTION MANUAL
12-2
12.2 Installation Condition
When installing the weighing machine, satisfy the following installation conditions in order to operate
the weighing machine effectively, maintain precision and perform weighing safely.
• When installing the weighing machine, observe the installation conditions.
Inappropriate installation may cause malfunction or damage to the weighing
machine.
• The power source specifications vary depending on customer. Observe the power
specifications in the contract.
• The weighing machine weight varies depending on the customer. Refer to the specifications
issued at the order.
Table 12-1 Installation Conditions
Item Condition
Operation environment Avoid direct sunlight.
• Room temperature: 0 to 40 deg C.
• Room humidity: 35 to 85% R.H. (No condensation is allowed.)
No dust is allowed.
There should be sufficient light to take product photos with a camera.
Installation surface The floor should have a steady, horizontal surface without vibrations.
Installation space There should be a working space around the weighing machine for maintenance and
inspections.
Static electricity Make sure to install the parts appropriately in order to avoid unearthed metal pieces.
Radio interference Do not place the weighing machine close to radio equipment or sources of radio interference.
Air
(For WP specifications)
Dry air.
Pressure: 0.5 MPa to 0.6 MPa.
(5 kgf/cm
2
to 6 kgf/cm
2
)
Power
(For standard specifications)
200 to 240V, 50/60 Hz. (Single phase)
Voltage fluctuation: within ±10%.
Frequency fluctuation: within ±5%.
Do not share the power source with weighing machines that may emit noises.
Weight
(For standard specifications)
750 kg.