CCW-R-2**B INSTRUCTION MANUAL 9 CLEANUP PROCEDURES
9-9
9.4.1.2 Dispersion Table
• When cleaning the dispersion table, do not push it down.
Doing so may damage the weight sensor.
1. Remove the hexagon bolts from the dispersion
table, and remove the dispersion table from the
device.
• For the separate type dispersion
table, the operator should not
perform this procedure.
• For the non-separate type dispersion
table, turn the dispersion table
counterclockwise (turn to the left) to
remove.
2. After washing and sterilizing, rinse with water
and dry. (For the washing and sterilization
methods, refer to “Table 9-4 Washing and
Sterilization Methods of Dispersion Table”.)
3. Reinstall in the reverse order of the removal.
4. Make sure the dispersion table is installed
securely.
• Perform the installation of the
dispersion table after installing the
radial troughs.
Fig.9-5 Separate Type Dispersion Table
Fig.9-6 Non-separate Type Dispersion Table
Table 9-4 Washing and Sterilization Methods of Dispersion Table
Washing method Immersion cleaning (Neutral detergent)
Sterilization method Immersion sterilization.
Warm water (80 to 90 deg C): 30 minutes.
Or,
sodium hypochlorite (available chlorine concentration 250 ppm): 20 minutes.