9 CLEANUP PROCEDURES CCW-R-2**B INSTRUCTION MANUAL
9-14
9.4.1.7 Timing Hopper
1. Loose the butterfly nut of the drive shaft, and
disconnect the timing hopper from the drive
unit.
Fig.9-14 Timing Hopper Overview
2. Slightly lift the drive unit side of the timing
hopper, and remove the timing hopper.
3. After washing and sterilizing, rinse with water
and dry. (For the washing and sterilization
methods, refer to “Table 9-9 Washing and
Sterilization Methods of Timing Hopper”)
4. Reinstall in the reverse order of the removal.
5. Make sure the timing hopper is installed
securely.
Fig.9-15 Timing Hopper Removal
Table 9-9 Washing and Sterilization Methods of Timing Hopper
Washing method Immersion cleaning. (Neutral detergent)
Sterilization
method
Immersion sterilization.
Warm water (80 to 90 deg C): 30 minutes.
Or,
sodium hypochlorite (available chlorine concentration 250 ppm): 20 minutes.